> Departamento de Engenharia Química
4
>
5
> Mestrado Integrado em Engenharia Química
6
>
7
> Integração e intensificação de processos
8
>
9
> Shell and Tubes Heat Exchangers
10
>
11
> **Docente** **Responsável:**
12
>
13
> Nuno Manuel Clemente de Oliveira
14
>
15
> **Integrantes** **do** **grupo:**
16
17
João Victor Vieira
18
19
> Matteo Gecchele
20
21
22
> **Introduction** **&** **Structure**
23
>
24
> The most common type of heat exchanger is the shell-and-tube, usually
25
> used in a lot of industrial applications. This type of heat exchanger
26
> has large number of tubes, sometimes several hundred, packed in a
27
> shell with their axes parallel to that of the shell. The heat transfer
28
> takes place between two fluid, one flowing inside the tubes and one
29
> flowing outside the tubes through the shell. Baffles are commonly
30
> placed in the shell to force the shell-side fluid to flow across the
31
> shell to enhance heat transfer, to maintain uniform spacing between
32
> the tubes and, also in order to maintain the turbulent flow inside the
33
> exchanger. The baffle spacing is usually not greater than a distance
34
> equal to the inside diameter or closer than a distance equal to
35
> one-fifth the inside diameter of the shell.
36
>
37
> Usually the shell-and-tube heat exchangers have large size and weight,
38
> and for this reason they are not using in automotive and aircraft
39
> applications. At both ends of the shell, the tubes open to some large
40
> flow areas, called headers, where the tube-side fluid accumulates
41
> before entering the tubes and after leaving them.
62c67d João Lopes 2025-03-13 12:01:58
42
>![](./xvze01o4.png)
374ad8 João Lopes 2025-03-13 11:57:41
43
> Shell-and-tube heat exchangers are further classified according to the
44
> number of shell and tube passes involved. Heat exchangers in which all
45
> the tubes make one U-turn in the shell, for example, are called
46
> one-shell-pass and two-tube-passes heat exchangers. Likewise, a heat
47
> exchanger that involves two passes in the shell and four passes in the
48
> tubes is called a two-shell- passes and four-tube-passes heat
49
> exchanger.
50
62c67d João Lopes 2025-03-13 12:01:58
51
![](./tnci3l31.png)![](./cncqllod.png)
52
374ad8 João Lopes 2025-03-13 11:57:41
53
54
> **Operation** **principle**
55
>
56
> In order to calculate the temperature difference ∆𝑡 in a 1-2
57
> exchanger, it is necessary to make some assumptions:
58
>
59
> 1\. The shell fluid temperature is an average isothermal temperature
60
> at any cross section
61
>
62
> 2\. There is an equal amount of heating surface in each pass 3. The
63
> overall coefficient of heat transfer is constant
64
>
65
> 4\. The specific heat of each fluid is constant 5. The flowrate of
66
> each fluid is constant
67
>
68
> 6\. There are not phase change (evaporation or condensation) in a part
69
> of the exchanger
70
>
71
> 7\. Heat losses are negligible
72
>
73
> The overall heat balance where ∆𝑡 is the true difference of
74
> temperatures, is:
75
>
76
> 𝑄 = 𝑈𝐴∆𝑡 = 𝑊𝐶(𝑇 − 𝑇 ) = 𝑤𝑐(𝑡2 − 𝑡1) where U is the heat transfer
77
> coefficient and A is the surface of contact.
78
>
79
> Shell-and-tube heat exchangers are complicated devices and the
80
> simplified approaches should be used with care. In fact, it is assumed
81
> that the overall heat transfer coefficient U is constant throughout
82
> the heat exchanger and that the convection heat transfer coefficients
83
> can be predicted using the convection correlations. However, in some
84
> practical application, the predicted value of U can exceed 30 percent.
85
> Thus, it is natural to tend to overdesign the heat exchangers in order
86
> to avoid unpleasant surprises.
87
>
88
> Heat transfer enhancement in heat exchangers is usually accompanied by
89
> increased
90
>
91
> pressure drop, and this causes higher pumping power. Therefore, any
92
> gain from the enhancement in heat transfer should be balanced against
93
> the cost of the accompanying pressure drop. Also, some thought should
94
> be given to which fluid should pass through the tube side and which
95
> through the shell side. Usually, the more viscous fluid is more
96
> suitable for the shell side (larger passage area and lower pressure
97
> drop) and the fluid with the higher pressure for the tube side.
98
>
99
> Usually, it is convenient to relate the equivalent temperature
100
> difference to the log
101
>
102
> mean temperature difference relation for the counter-flow case as
103
>
104
> ∆ 𝑙𝑚 = 𝐹∆ 𝑙𝑚,𝐶𝐹
105
106
where *F* is the correction factor**,** which depends on the geometry of
107
the heat exchanger and the inlet and outlet temperatures of the hot and
108
cold fluid streams. The
109
110
> ∆𝑇𝑚,𝐶𝐹 is the log mean temperature difference for the case of a
111
> counter-flow heat exchanger with the same inlet and outlet
112
> temperatures.
113
>
114
> The correction factor *F* for a shell-and-tube heat exchanger is shown
115
> in the figures below versus two temperature ratios *P* and *R* defined
116
> as
117
>
118
> 𝑡2 − 𝑡1 𝑇 − 𝑡1
119
>
120
> 𝑇 − 𝑇 𝑡2 − 𝑡1
121
>
122
> where the subscripts 1 and 2 represent the inlet and outlet*,*
123
> respectively. Note that for
124
>
125
> a shell-and-tube heat exchanger, *T* and *t* represent the shell-side
126
> and tube-side temperatures, respectively.
127
62c67d João Lopes 2025-03-13 12:01:58
128
![](./gklfx0zi.png)
374ad8 João Lopes 2025-03-13 11:57:41
129
130
> **Factors** **that** **influence** **performances** *Fouling:*
131
>
132
> The performance of heat exchangers usually deteriorates with time as a
133
> result of accumulation of deposits on heat transfer surfaces. The
134
> layer of deposits represents additional resistance to heat transfer
135
> and this causes a decrease of the rate of heat transfer in a heat
136
> exchanger. The net effect of these accumulations on heat transfer is
137
> represented by a fouling factor, which is a measure of the thermal
138
> resistance introduced by fouling.
139
>
140
> For a shell-and-tube heat exchanger it possible to write the overall
141
> heat transfer relation as
142
>
143
> 𝑈𝐴𝑠 = 𝑈𝐴𝑖 = 𝑈0𝐴0 = 𝑅 = ℎ𝑖𝐴𝑖 + 𝐴𝑖𝑖 + ln⁡𝑈0𝐴0 𝑖) + 𝐴0 + ℎ0𝐴0
144
>
145
> where 𝐴𝑖 = 𝐷𝐿 and 𝐴0 = 𝐷0𝐿 L are the areas of inner and outer
146
> surfaces, and 𝑅,𝑖 and 𝑅,0 are the fouling factors at those surfaces.
147
>
148
> *Heat* *transfer* *rate:*
149
>
150
> The heat transfer rate is the most important parameter of a heat
151
> exchanger. A heat exchanger should be capable of transferring heat at
152
> the specified rate in order to achieve the desired temperature change
153
> of the fluid at the specified mass flow rate.
154
>
155
> *Size* *and* *Weight:*
156
>
157
> The heat exchanger is better if it is smaller and lighter, in
158
> particular, in the automotive and aerospace industries, where size and
159
> weight requirements are most stringent. For this reason,
160
> shell-and-tube heat exchangers cannot be used in this type of
161
> application. Also, a larger heat exchanger normally carries a higher
162
> price tag. The space available for the heat exchanger in some cases
163
> limits the length of the tubes that can be used.
164
>
165
> *Material:*
166
>
167
> The thermal and structural stress effects need not be considered at
168
> pressures below 15 *atm* or temperatures below 150*°C*. But these
169
> effects are major considerations above 70 *atm* or 550*°C* and
170
> seriously limit the acceptable materials of the heat exchanger.
171
>
172
> A temperature difference of 50*°C* or more between the tubes and the
173
> shell will probably pose differential thermal expansion problems and
174
> needs to be considered. In the case of corrosive fluids, we may have
175
> to select expensive corrosion-resistant materials such as stainless
176
> steel or even titanium.
177
>
178
> **Cost**
179
>
180
> The purchase cost of a shell and tube depends on the rear head type
181
> and on the heat transfer
182
>
183
> area (size factor). The relationship between the purchase cost and the
184
> size factor is
185
>
186
> represented in the graph below
187
62c67d João Lopes 2025-03-13 12:01:58
188
![](./s1x5d1ti.png)
374ad8 João Lopes 2025-03-13 11:57:41
189
190
> Both fluids are usually forced to flow by pumps or fans that consume
191
> electrical power. The annual cost of electricity associated with the
192
> operation of the pumps and fans can be determined from
193
>
194
> 𝑂𝑝𝑒𝑟𝑎𝑡𝑖𝑛𝑔⁡𝐶𝑜𝑠𝑡 = 𝑃𝑢𝑚𝑝𝑖𝑛𝑔⁡𝑃𝑜𝑤𝑒𝑟⁡\[𝑘𝑊\] × 𝐻𝑜𝑢𝑟𝑠⁡𝑜𝑓⁡𝑂𝑝𝑒𝑟𝑎𝑡𝑖𝑜𝑛⁡\[ℎ\] ×
195
> 𝑃𝑟𝑖𝑐𝑒𝑜𝑓⁡𝐸𝑙𝑒𝑐𝑟𝑖𝑐𝑖𝑡𝑦⁡\[\$ 𝑘𝑊ℎ\]
196
>
197
> where the pumping power is the total electrical power consumed by the
198
> motors of the pumps and fans.
199
>
200
> Minimizing the pressure drop and the mass flow rate of the fluids will
201
> minimize the operating cost of the heat exchanger, but it will
202
> maximize the size of the heat exchanger and thus the initial cost. As
203
> a rule of thumb, doubling the mass flow rate will reduce the initial
204
> cost by half but will increase the pumping power requirements by a
205
> factor of roughly eight. Typically, fluid velocities encountered in
206
> heat exchangers range between 0.7 and 7 m/s for liquids and between 3
207
> and 30 m/s for gases. Low velocities are helpful in avoiding erosion,
208
> tube vibrations, and noise as well as pressure drop.
209
>
210
> **Advantages**:
211
>
212
> *Size:*
213
>
214
> Shell-and-tube heat exchangers are capable of providing a larger
215
> surface area for heat transfer to take place while having a shorter
216
> length overall due to presence of multiple tubes.
217
>
218
> *Heat* *duty:*
219
>
220
> Shell-and-tube heat exchangers can handle higher temperatures and
221
> pressures and hence higher heat duty. This is because besides
222
> providing a higher overall heat transfer coefficient, additions can
223
> also be made to negate thermal expansion effects and the thickness can
224
> also be varied (more in the next point).
225
>
226
> *Versatility:*
227
>
228
> From the design point of view, shell-and-tube heat exchangers are the
229
> most versatile of all heat exchangers. Being tubular in shape, heads /
230
> closures of required shape and thickness can be used. The number of
231
> tubes and tube pitch can be selected according to operating
232
> conditions. Expansion bellows can be used to negate thermal expansion
233
> effects, baffles if different cuts and spacings can be used to
234
> influence the overall heat transfer coefficients and there's even
235
> something called a floating head which can be added to negate thermal
236
> expansion of the tubes. The number of passes on shell side and tube
237
> side can be altered as well.
238
>
239
> **Disadvantages**:
240
>
241
> *Size:*
242
>
243
> This can also be a disadvantage as at lower heat duty, there are more
244
> compact heat exchangers such as plate type exchanger. Also, the
245
> absence of hairpin bends causes shell-and-tube heat exchangers to take
246
> up more space than double pipe heat exchangers in some cases.
247
>
248
> *Maintenance:*
249
>
250
> Cleaning of tubes is difficult and fouling is always an issue when
251
> overall heat transfer coefficient is addressed. This requires periodic
252
> cleaning of the shell as well as the tubes. Cleaning tubes may be more
253
> difficult if the pitch is triangular.
254
>
255
> **Utilities**
256
>
257
> The selection of utilities to be used in the shell and tubes tube
258
> exchanger takes into
259
>
260
> account the type of industry in which it is being operated and the
261
> desired parameters, such as the required power, thermal stability and
262
> thermal capacity.
263
>
264
> *Cooling* *Water*:
265
>
266
> Cooling water is used to cool and/or condense currents. The cooling
267
> water circulates inside heat exchangers. About 80% of the temperature
268
> reduction is due to the evaporation of the cooling water and the
269
> transfer of heat to the surrounding air.
270
>
271
> *Steam:*
272
>
273
> Steam is the most common heat utility used in the chemical industry
274
> and can be used to power pumps, compressors and heat exchangers. Using
275
> steam allows a more efficient heat source since the heat of
276
> condensation of the steam is quite high, which translates into a high
277
> yield per utility mass, at a constant temperature. Another reason is
278
> that steam is non-flammable, non-toxic and inert to various process
279
> fluids (more safe than other utilities like oil).
280
>
281
> **Conclusion**
282
>
62c67d João Lopes 2025-03-13 12:01:58
283
> The simple design of a shell and tube heat exchanger makes it an ideal
374ad8 João Lopes 2025-03-13 11:57:41
284
> cooling solution for a wide variety of applications and as a
285
> consequence shell-and-tube heat exchangers are very popular and
286
> commonly found in industrial use.
287
>
288
> **References**
289
>
290
> \[1\] Notes on Transfer Phenomena II, Professor Maria Graça Carvalho,
291
> 2018/2019;
292
>
293
> \[2\] Warren D. Seider, University of Pennsylvania
294
>
295
> \[3\] Heat Transfer by Changel 2nd Edition
296
>
297
> \[4\] Heat Transfer by Holman 6th Edition