> Departamento de Engenharia Química
5
>
6
> Mestrado Integrado em Engenharia Química
7
>
8
> Integração e intensificação de processos
9
>
10
> Shell and Tubes Heat Exchangers
11
>
12
> **Docente** **Responsável:**
13
>
14
> Nuno Manuel Clemente de Oliveira
15
>
16
> **Integrantes** **do** **grupo:**
17
18
João Victor Vieira
19
20
> Matteo Gecchele
21
22
<img src="./xvze01o4.png"
23
style="width:5.90556in;height:2.24583in" />
24
25
> **Introduction** **&** **Structure**
26
>
27
> The most common type of heat exchanger is the shell-and-tube, usually
28
> used in a lot of industrial applications. This type of heat exchanger
29
> has large number of tubes, sometimes several hundred, packed in a
30
> shell with their axes parallel to that of the shell. The heat transfer
31
> takes place between two fluid, one flowing inside the tubes and one
32
> flowing outside the tubes through the shell. Baffles are commonly
33
> placed in the shell to force the shell-side fluid to flow across the
34
> shell to enhance heat transfer, to maintain uniform spacing between
35
> the tubes and, also in order to maintain the turbulent flow inside the
36
> exchanger. The baffle spacing is usually not greater than a distance
37
> equal to the inside diameter or closer than a distance equal to
38
> one-fifth the inside diameter of the shell.
39
>
40
> Usually the shell-and-tube heat exchangers have large size and weight,
41
> and for this reason they are not using in automotive and aircraft
42
> applications. At both ends of the shell, the tubes open to some large
43
> flow areas, called headers, where the tube-side fluid accumulates
44
> before entering the tubes and after leaving them.
45
>
46
> Shell-and-tube heat exchangers are further classified according to the
47
> number of shell and tube passes involved. Heat exchangers in which all
48
> the tubes make one U-turn in the shell, for example, are called
49
> one-shell-pass and two-tube-passes heat exchangers. Likewise, a heat
50
> exchanger that involves two passes in the shell and four passes in the
51
> tubes is called a two-shell- passes and four-tube-passes heat
52
> exchanger.
53
54
<img src="./tnci3l31.png"
55
style="width:2.85417in;height:1.78125in" /><img src="./cncqllod.png"
56
style="width:2.57292in;height:2.02083in" />
57
58
> **Operation** **principle**
59
>
60
> In order to calculate the temperature difference ∆𝑡 in a 1-2
61
> exchanger, it is necessary to make some assumptions:
62
>
63
> 1\. The shell fluid temperature is an average isothermal temperature
64
> at any cross section
65
>
66
> 2\. There is an equal amount of heating surface in each pass 3. The
67
> overall coefficient of heat transfer is constant
68
>
69
> 4\. The specific heat of each fluid is constant 5. The flowrate of
70
> each fluid is constant
71
>
72
> 6\. There are not phase change (evaporation or condensation) in a part
73
> of the exchanger
74
>
75
> 7\. Heat losses are negligible
76
>
77
> The overall heat balance where ∆𝑡 is the true difference of
78
> temperatures, is:
79
>
80
> 𝑄 = 𝑈𝐴∆𝑡 = 𝑊𝐶(𝑇 − 𝑇 ) = 𝑤𝑐(𝑡2 − 𝑡1) where U is the heat transfer
81
> coefficient and A is the surface of contact.
82
>
83
> Shell-and-tube heat exchangers are complicated devices and the
84
> simplified approaches should be used with care. In fact, it is assumed
85
> that the overall heat transfer coefficient U is constant throughout
86
> the heat exchanger and that the convection heat transfer coefficients
87
> can be predicted using the convection correlations. However, in some
88
> practical application, the predicted value of U can exceed 30 percent.
89
> Thus, it is natural to tend to overdesign the heat exchangers in order
90
> to avoid unpleasant surprises.
91
>
92
> Heat transfer enhancement in heat exchangers is usually accompanied by
93
> increased
94
>
95
> pressure drop, and this causes higher pumping power. Therefore, any
96
> gain from the enhancement in heat transfer should be balanced against
97
> the cost of the accompanying pressure drop. Also, some thought should
98
> be given to which fluid should pass through the tube side and which
99
> through the shell side. Usually, the more viscous fluid is more
100
> suitable for the shell side (larger passage area and lower pressure
101
> drop) and the fluid with the higher pressure for the tube side.
102
>
103
> Usually, it is convenient to relate the equivalent temperature
104
> difference to the log
105
>
106
> mean temperature difference relation for the counter-flow case as
107
>
108
> ∆ 𝑙𝑚 = 𝐹∆ 𝑙𝑚,𝐶𝐹
109
110
where *F* is the correction factor**,** which depends on the geometry of
111
the heat exchanger and the inlet and outlet temperatures of the hot and
112
cold fluid streams. The
113
114
> ∆𝑇𝑚,𝐶𝐹 is the log mean temperature difference for the case of a
115
> counter-flow heat exchanger with the same inlet and outlet
116
> temperatures.
117
>
118
> The correction factor *F* for a shell-and-tube heat exchanger is shown
119
> in the figures below versus two temperature ratios *P* and *R* defined
120
> as
121
>
122
> 𝑡2 − 𝑡1 𝑇 − 𝑡1
123
>
124
> 𝑇 − 𝑇 𝑡2 − 𝑡1
125
>
126
> where the subscripts 1 and 2 represent the inlet and outlet*,*
127
> respectively. Note that for
128
>
129
> a shell-and-tube heat exchanger, *T* and *t* represent the shell-side
130
> and tube-side temperatures, respectively.
131
132
<img src="./gklfx0zi.png"
133
style="width:5.02431in;height:4.35569in" />
134
135
> **Factors** **that** **influence** **performances** *Fouling:*
136
>
137
> The performance of heat exchangers usually deteriorates with time as a
138
> result of accumulation of deposits on heat transfer surfaces. The
139
> layer of deposits represents additional resistance to heat transfer
140
> and this causes a decrease of the rate of heat transfer in a heat
141
> exchanger. The net effect of these accumulations on heat transfer is
142
> represented by a fouling factor, which is a measure of the thermal
143
> resistance introduced by fouling.
144
>
145
> For a shell-and-tube heat exchanger it possible to write the overall
146
> heat transfer relation as
147
>
148
> 𝑈𝐴𝑠 = 𝑈𝐴𝑖 = 𝑈0𝐴0 = 𝑅 = ℎ𝑖𝐴𝑖 + 𝐴𝑖𝑖 + ln⁡𝑈0𝐴0 𝑖) + 𝐴0 + ℎ0𝐴0
149
>
150
> where 𝐴𝑖 = 𝐷𝐿 and 𝐴0 = 𝐷0𝐿 L are the areas of inner and outer
151
> surfaces, and 𝑅,𝑖 and 𝑅,0 are the fouling factors at those surfaces.
152
>
153
> *Heat* *transfer* *rate:*
154
>
155
> The heat transfer rate is the most important parameter of a heat
156
> exchanger. A heat exchanger should be capable of transferring heat at
157
> the specified rate in order to achieve the desired temperature change
158
> of the fluid at the specified mass flow rate.
159
>
160
> *Size* *and* *Weight:*
161
>
162
> The heat exchanger is better if it is smaller and lighter, in
163
> particular, in the automotive and aerospace industries, where size and
164
> weight requirements are most stringent. For this reason,
165
> shell-and-tube heat exchangers cannot be used in this type of
166
> application. Also, a larger heat exchanger normally carries a higher
167
> price tag. The space available for the heat exchanger in some cases
168
> limits the length of the tubes that can be used.
169
>
170
> *Material:*
171
>
172
> The thermal and structural stress effects need not be considered at
173
> pressures below 15 *atm* or temperatures below 150*°C*. But these
174
> effects are major considerations above 70 *atm* or 550*°C* and
175
> seriously limit the acceptable materials of the heat exchanger.
176
>
177
> A temperature difference of 50*°C* or more between the tubes and the
178
> shell will probably pose differential thermal expansion problems and
179
> needs to be considered. In the case of corrosive fluids, we may have
180
> to select expensive corrosion-resistant materials such as stainless
181
> steel or even titanium.
182
>
183
> **Cost**
184
>
185
> The purchase cost of a shell and tube depends on the rear head type
186
> and on the heat transfer
187
>
188
> area (size factor). The relationship between the purchase cost and the
189
> size factor is
190
>
191
> represented in the graph below
192
193
<img src="./s1x5d1ti.png"
194
style="width:4.86667in;height:3.36917in" />
195
196
> Both fluids are usually forced to flow by pumps or fans that consume
197
> electrical power. The annual cost of electricity associated with the
198
> operation of the pumps and fans can be determined from
199
>
200
> 𝑂𝑝𝑒𝑟𝑎𝑡𝑖𝑛𝑔⁡𝐶𝑜𝑠𝑡 = 𝑃𝑢𝑚𝑝𝑖𝑛𝑔⁡𝑃𝑜𝑤𝑒𝑟⁡\[𝑘𝑊\] × 𝐻𝑜𝑢𝑟𝑠⁡𝑜𝑓⁡𝑂𝑝𝑒𝑟𝑎𝑡𝑖𝑜𝑛⁡\[ℎ\] ×
201
> 𝑃𝑟𝑖𝑐𝑒𝑜𝑓⁡𝐸𝑙𝑒𝑐𝑟𝑖𝑐𝑖𝑡𝑦⁡\[\$ 𝑘𝑊ℎ\]
202
>
203
> where the pumping power is the total electrical power consumed by the
204
> motors of the pumps and fans.
205
>
206
> Minimizing the pressure drop and the mass flow rate of the fluids will
207
> minimize the operating cost of the heat exchanger, but it will
208
> maximize the size of the heat exchanger and thus the initial cost. As
209
> a rule of thumb, doubling the mass flow rate will reduce the initial
210
> cost by half but will increase the pumping power requirements by a
211
> factor of roughly eight. Typically, fluid velocities encountered in
212
> heat exchangers range between 0.7 and 7 m/s for liquids and between 3
213
> and 30 m/s for gases. Low velocities are helpful in avoiding erosion,
214
> tube vibrations, and noise as well as pressure drop.
215
>
216
> **Advantages**:
217
>
218
> *Size:*
219
>
220
> Shell-and-tube heat exchangers are capable of providing a larger
221
> surface area for heat transfer to take place while having a shorter
222
> length overall due to presence of multiple tubes.
223
>
224
> *Heat* *duty:*
225
>
226
> Shell-and-tube heat exchangers can handle higher temperatures and
227
> pressures and hence higher heat duty. This is because besides
228
> providing a higher overall heat transfer coefficient, additions can
229
> also be made to negate thermal expansion effects and the thickness can
230
> also be varied (more in the next point).
231
>
232
> *Versatility:*
233
>
234
> From the design point of view, shell-and-tube heat exchangers are the
235
> most versatile of all heat exchangers. Being tubular in shape, heads /
236
> closures of required shape and thickness can be used. The number of
237
> tubes and tube pitch can be selected according to operating
238
> conditions. Expansion bellows can be used to negate thermal expansion
239
> effects, baffles if different cuts and spacings can be used to
240
> influence the overall heat transfer coefficients and there's even
241
> something called a floating head which can be added to negate thermal
242
> expansion of the tubes. The number of passes on shell side and tube
243
> side can be altered as well.
244
>
245
> **Disadvantages**:
246
>
247
> *Size:*
248
>
249
> This can also be a disadvantage as at lower heat duty, there are more
250
> compact heat exchangers such as plate type exchanger. Also, the
251
> absence of hairpin bends causes shell-and-tube heat exchangers to take
252
> up more space than double pipe heat exchangers in some cases.
253
>
254
> *Maintenance:*
255
>
256
> Cleaning of tubes is difficult and fouling is always an issue when
257
> overall heat transfer coefficient is addressed. This requires periodic
258
> cleaning of the shell as well as the tubes. Cleaning tubes may be more
259
> difficult if the pitch is triangular.
260
>
261
> **Utilities**
262
>
263
> The selection of utilities to be used in the shell and tubes tube
264
> exchanger takes into
265
>
266
> account the type of industry in which it is being operated and the
267
> desired parameters, such as the required power, thermal stability and
268
> thermal capacity.
269
>
270
> *Cooling* *Water*:
271
>
272
> Cooling water is used to cool and/or condense currents. The cooling
273
> water circulates inside heat exchangers. About 80% of the temperature
274
> reduction is due to the evaporation of the cooling water and the
275
> transfer of heat to the surrounding air.
276
>
277
> *Steam:*
278
>
279
> Steam is the most common heat utility used in the chemical industry
280
> and can be used to power pumps, compressors and heat exchangers. Using
281
> steam allows a more efficient heat source since the heat of
282
> condensation of the steam is quite high, which translates into a high
283
> yield per utility mass, at a constant temperature. Another reason is
284
> that steam is non-flammable, non-toxic and inert to various process
285
> fluids (more safe than other utilities like oil).
286
>
287
> **Conclusion**
288
>
289
> The simple design of a shell and tube heat exchanger makes it an ideal
290
> cooling solution for a wide variety of applications and as a
291
> consequence shell-and-tube heat exchangers are very popular and
292
> commonly found in industrial use.
293
>
294
> **References**
295
>
296
> \[1\] Notes on Transfer Phenomena II, Professor Maria Graça Carvalho,
297
> 2018/2019;
298
>
299
> \[2\] Warren D. Seider, University of Pennsylvania
300
>
301
> \[3\] Heat Transfer by Changel 2nd Edition
302
>
303
> \[4\] Heat Transfer by Holman 6th Edition