Commit 90d22b

2025-03-13 11:02:20 João Lopes: Added attachment(s): Permutadores_de_Carcaca_e_Tubo.md.
/dev/null .. Utilidades industriais/Equipamentos/Permutadores_de_Carcaca_e_Tubo.md
@@ 0,0 1,303 @@
+<img src="./fa4pc54n.png"
+style="width:3.085in;height:1.71389in" />
+
+> Departamento de Engenharia Química
+>
+> Mestrado Integrado em Engenharia Química
+>
+> Integração e intensificação de processos
+>
+> Shell and Tubes Heat Exchangers
+>
+> **Docente** **Responsável:**
+>
+> Nuno Manuel Clemente de Oliveira
+>
+> **Integrantes** **do** **grupo:**
+
+João Victor Vieira
+
+> Matteo Gecchele
+
+<img src="./xvze01o4.png"
+style="width:5.90556in;height:2.24583in" />
+
+> **Introduction** **&** **Structure**
+>
+> The most common type of heat exchanger is the shell-and-tube, usually
+> used in a lot of industrial applications. This type of heat exchanger
+> has large number of tubes, sometimes several hundred, packed in a
+> shell with their axes parallel to that of the shell. The heat transfer
+> takes place between two fluid, one flowing inside the tubes and one
+> flowing outside the tubes through the shell. Baffles are commonly
+> placed in the shell to force the shell-side fluid to flow across the
+> shell to enhance heat transfer, to maintain uniform spacing between
+> the tubes and, also in order to maintain the turbulent flow inside the
+> exchanger. The baffle spacing is usually not greater than a distance
+> equal to the inside diameter or closer than a distance equal to
+> one-fifth the inside diameter of the shell.
+>
+> Usually the shell-and-tube heat exchangers have large size and weight,
+> and for this reason they are not using in automotive and aircraft
+> applications. At both ends of the shell, the tubes open to some large
+> flow areas, called headers, where the tube-side fluid accumulates
+> before entering the tubes and after leaving them.
+>
+> Shell-and-tube heat exchangers are further classified according to the
+> number of shell and tube passes involved. Heat exchangers in which all
+> the tubes make one U-turn in the shell, for example, are called
+> one-shell-pass and two-tube-passes heat exchangers. Likewise, a heat
+> exchanger that involves two passes in the shell and four passes in the
+> tubes is called a two-shell- passes and four-tube-passes heat
+> exchanger.
+
+<img src="./tnci3l31.png"
+style="width:2.85417in;height:1.78125in" /><img src="./cncqllod.png"
+style="width:2.57292in;height:2.02083in" />
+
+> **Operation** **principle**
+>
+> In order to calculate the temperature difference ∆𝑡 in a 1-2
+> exchanger, it is necessary to make some assumptions:
+>
+> 1\. The shell fluid temperature is an average isothermal temperature
+> at any cross section
+>
+> 2\. There is an equal amount of heating surface in each pass 3. The
+> overall coefficient of heat transfer is constant
+>
+> 4\. The specific heat of each fluid is constant 5. The flowrate of
+> each fluid is constant
+>
+> 6\. There are not phase change (evaporation or condensation) in a part
+> of the exchanger
+>
+> 7\. Heat losses are negligible
+>
+> The overall heat balance where ∆𝑡 is the true difference of
+> temperatures, is:
+>
+> 𝑄 = 𝑈𝐴∆𝑡 = 𝑊𝐶(𝑇 − 𝑇 ) = 𝑤𝑐(𝑡2 − 𝑡1) where U is the heat transfer
+> coefficient and A is the surface of contact.
+>
+> Shell-and-tube heat exchangers are complicated devices and the
+> simplified approaches should be used with care. In fact, it is assumed
+> that the overall heat transfer coefficient U is constant throughout
+> the heat exchanger and that the convection heat transfer coefficients
+> can be predicted using the convection correlations. However, in some
+> practical application, the predicted value of U can exceed 30 percent.
+> Thus, it is natural to tend to overdesign the heat exchangers in order
+> to avoid unpleasant surprises.
+>
+> Heat transfer enhancement in heat exchangers is usually accompanied by
+> increased
+>
+> pressure drop, and this causes higher pumping power. Therefore, any
+> gain from the enhancement in heat transfer should be balanced against
+> the cost of the accompanying pressure drop. Also, some thought should
+> be given to which fluid should pass through the tube side and which
+> through the shell side. Usually, the more viscous fluid is more
+> suitable for the shell side (larger passage area and lower pressure
+> drop) and the fluid with the higher pressure for the tube side.
+>
+> Usually, it is convenient to relate the equivalent temperature
+> difference to the log
+>
+> mean temperature difference relation for the counter-flow case as
+>
+> ∆ 𝑙𝑚 = 𝐹∆ 𝑙𝑚,𝐶𝐹
+
+where *F* is the correction factor**,** which depends on the geometry of
+the heat exchanger and the inlet and outlet temperatures of the hot and
+cold fluid streams. The
+
+> ∆𝑇𝑚,𝐶𝐹 is the log mean temperature difference for the case of a
+> counter-flow heat exchanger with the same inlet and outlet
+> temperatures.
+>
+> The correction factor *F* for a shell-and-tube heat exchanger is shown
+> in the figures below versus two temperature ratios *P* and *R* defined
+> as
+>
+> 𝑡2 − 𝑡1 𝑇 − 𝑡1
+>
+> 𝑇 − 𝑇 𝑡2 − 𝑡1
+>
+> where the subscripts 1 and 2 represent the inlet and outlet*,*
+> respectively. Note that for
+>
+> a shell-and-tube heat exchanger, *T* and *t* represent the shell-side
+> and tube-side temperatures, respectively.
+
+<img src="./gklfx0zi.png"
+style="width:5.02431in;height:4.35569in" />
+
+> **Factors** **that** **influence** **performances** *Fouling:*
+>
+> The performance of heat exchangers usually deteriorates with time as a
+> result of accumulation of deposits on heat transfer surfaces. The
+> layer of deposits represents additional resistance to heat transfer
+> and this causes a decrease of the rate of heat transfer in a heat
+> exchanger. The net effect of these accumulations on heat transfer is
+> represented by a fouling factor, which is a measure of the thermal
+> resistance introduced by fouling.
+>
+> For a shell-and-tube heat exchanger it possible to write the overall
+> heat transfer relation as
+>
+> 𝑈𝐴𝑠 = 𝑈𝐴𝑖 = 𝑈0𝐴0 = 𝑅 = ℎ𝑖𝐴𝑖 + 𝐴𝑖𝑖 + ln⁡𝑈0𝐴0 𝑖) + 𝐴0 + ℎ0𝐴0
+>
+> where 𝐴𝑖 = 𝐷𝐿 and 𝐴0 = 𝐷0𝐿 L are the areas of inner and outer
+> surfaces, and 𝑅,𝑖 and 𝑅,0 are the fouling factors at those surfaces.
+>
+> *Heat* *transfer* *rate:*
+>
+> The heat transfer rate is the most important parameter of a heat
+> exchanger. A heat exchanger should be capable of transferring heat at
+> the specified rate in order to achieve the desired temperature change
+> of the fluid at the specified mass flow rate.
+>
+> *Size* *and* *Weight:*
+>
+> The heat exchanger is better if it is smaller and lighter, in
+> particular, in the automotive and aerospace industries, where size and
+> weight requirements are most stringent. For this reason,
+> shell-and-tube heat exchangers cannot be used in this type of
+> application. Also, a larger heat exchanger normally carries a higher
+> price tag. The space available for the heat exchanger in some cases
+> limits the length of the tubes that can be used.
+>
+> *Material:*
+>
+> The thermal and structural stress effects need not be considered at
+> pressures below 15 *atm* or temperatures below 150*°C*. But these
+> effects are major considerations above 70 *atm* or 550*°C* and
+> seriously limit the acceptable materials of the heat exchanger.
+>
+> A temperature difference of 50*°C* or more between the tubes and the
+> shell will probably pose differential thermal expansion problems and
+> needs to be considered. In the case of corrosive fluids, we may have
+> to select expensive corrosion-resistant materials such as stainless
+> steel or even titanium.
+>
+> **Cost**
+>
+> The purchase cost of a shell and tube depends on the rear head type
+> and on the heat transfer
+>
+> area (size factor). The relationship between the purchase cost and the
+> size factor is
+>
+> represented in the graph below
+
+<img src="./s1x5d1ti.png"
+style="width:4.86667in;height:3.36917in" />
+
+> Both fluids are usually forced to flow by pumps or fans that consume
+> electrical power. The annual cost of electricity associated with the
+> operation of the pumps and fans can be determined from
+>
+> 𝑂𝑝𝑒𝑟𝑎𝑡𝑖𝑛𝑔⁡𝐶𝑜𝑠𝑡 = 𝑃𝑢𝑚𝑝𝑖𝑛𝑔⁡𝑃𝑜𝑤𝑒𝑟⁡\[𝑘𝑊\] × 𝐻𝑜𝑢𝑟𝑠⁡𝑜𝑓⁡𝑂𝑝𝑒𝑟𝑎𝑡𝑖𝑜𝑛⁡\[ℎ\] ×
+> 𝑃𝑟𝑖𝑐𝑒𝑜𝑓⁡𝐸𝑙𝑒𝑐𝑟𝑖𝑐𝑖𝑡𝑦⁡\[\$ 𝑘𝑊ℎ\]
+>
+> where the pumping power is the total electrical power consumed by the
+> motors of the pumps and fans.
+>
+> Minimizing the pressure drop and the mass flow rate of the fluids will
+> minimize the operating cost of the heat exchanger, but it will
+> maximize the size of the heat exchanger and thus the initial cost. As
+> a rule of thumb, doubling the mass flow rate will reduce the initial
+> cost by half but will increase the pumping power requirements by a
+> factor of roughly eight. Typically, fluid velocities encountered in
+> heat exchangers range between 0.7 and 7 m/s for liquids and between 3
+> and 30 m/s for gases. Low velocities are helpful in avoiding erosion,
+> tube vibrations, and noise as well as pressure drop.
+>
+> **Advantages**:
+>
+> *Size:*
+>
+> Shell-and-tube heat exchangers are capable of providing a larger
+> surface area for heat transfer to take place while having a shorter
+> length overall due to presence of multiple tubes.
+>
+> *Heat* *duty:*
+>
+> Shell-and-tube heat exchangers can handle higher temperatures and
+> pressures and hence higher heat duty. This is because besides
+> providing a higher overall heat transfer coefficient, additions can
+> also be made to negate thermal expansion effects and the thickness can
+> also be varied (more in the next point).
+>
+> *Versatility:*
+>
+> From the design point of view, shell-and-tube heat exchangers are the
+> most versatile of all heat exchangers. Being tubular in shape, heads /
+> closures of required shape and thickness can be used. The number of
+> tubes and tube pitch can be selected according to operating
+> conditions. Expansion bellows can be used to negate thermal expansion
+> effects, baffles if different cuts and spacings can be used to
+> influence the overall heat transfer coefficients and there's even
+> something called a floating head which can be added to negate thermal
+> expansion of the tubes. The number of passes on shell side and tube
+> side can be altered as well.
+>
+> **Disadvantages**:
+>
+> *Size:*
+>
+> This can also be a disadvantage as at lower heat duty, there are more
+> compact heat exchangers such as plate type exchanger. Also, the
+> absence of hairpin bends causes shell-and-tube heat exchangers to take
+> up more space than double pipe heat exchangers in some cases.
+>
+> *Maintenance:*
+>
+> Cleaning of tubes is difficult and fouling is always an issue when
+> overall heat transfer coefficient is addressed. This requires periodic
+> cleaning of the shell as well as the tubes. Cleaning tubes may be more
+> difficult if the pitch is triangular.
+>
+> **Utilities**
+>
+> The selection of utilities to be used in the shell and tubes tube
+> exchanger takes into
+>
+> account the type of industry in which it is being operated and the
+> desired parameters, such as the required power, thermal stability and
+> thermal capacity.
+>
+> *Cooling* *Water*:
+>
+> Cooling water is used to cool and/or condense currents. The cooling
+> water circulates inside heat exchangers. About 80% of the temperature
+> reduction is due to the evaporation of the cooling water and the
+> transfer of heat to the surrounding air.
+>
+> *Steam:*
+>
+> Steam is the most common heat utility used in the chemical industry
+> and can be used to power pumps, compressors and heat exchangers. Using
+> steam allows a more efficient heat source since the heat of
+> condensation of the steam is quite high, which translates into a high
+> yield per utility mass, at a constant temperature. Another reason is
+> that steam is non-flammable, non-toxic and inert to various process
+> fluids (more safe than other utilities like oil).
+>
+> **Conclusion**
+>
+> The simple design of a shell and tube heat exchanger makes it an ideal
+> cooling solution for a wide variety of applications and as a
+> consequence shell-and-tube heat exchangers are very popular and
+> commonly found in industrial use.
+>
+> **References**
+>
+> \[1\] Notes on Transfer Phenomena II, Professor Maria Graça Carvalho,
+> 2018/2019;
+>
+> \[2\] Warren D. Seider, University of Pennsylvania
+>
+> \[3\] Heat Transfer by Changel 2nd Edition
+>
+> \[4\] Heat Transfer by Holman 6th Edition
0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9